CORE CAT7A Indoor S/FTP Solid Bare Copper Cable, LSZH, 305m, 23AWG, CPR Dca, 1000MHz
- CAT7A Solid Bare Copper
- 1000MHz
- 23AWG
- Double Shielding: Overall Shielded Braiding & Individually Shielded Twisted-Pairs
- Low Smoke Zero Halogen (LSZH), Class Dca
- 25-Year Limited Warranty
Overview
CORE ULTRA series CAT7A cables have been tested to 1000MHz, the highest possible for a CAT7A cable to ensure lightning speeds. Each cable is performance optimized with 4 balanced and shielded twisted pairs with an outer braided shield to minimize Alien Near-End Crosstalk (A-NEXT) in the transmission compared to CAT6 whilst also improving Equal-Level Far-End Crosstalk (ELFEXT), Return Loss (RL) and Insertion Loss (IL).
Up to 10Gbps
Suitable for 1Gbps to 10Gbps up to 100m / 328feet.
CORE's Shielded-Pair Design & Alien Crosstalk
With CAT7A able to handle bandwidth up to 10Gbps (10GBASE-T), noise sensitivity increases up to the 1000MHz higher frequencies. When CAT7A cables are bundled with other CAT6A or CAT7A cables, noise is induced into the adjacent cables, referred to as alien crosstalk. This significantly impacts high-speed 10GBASE-T performance, having the potential to reduce speed, lose data and interrupt your network with downtime. CORE's balanced shielded-pair design virtually eliminates this as well as provides immunity to EMI and RF interference. Compared to CAT6A's shielding, this has the additional braided shield layer, forming a double shield in order to minimize alien crosstalk at the higher 1000MHz. Furthermore, the drain wire allows a continuous, low-resistance connection to the cable's metallic shield, resulting in very effective grounding to protect against electrical surges.
Fire Rating
Important where smoke emissions and toxic fumes could pose a risk to human life and sensitive equipment, there are various grades for a cable's fire performance. CORE Low Smoke Zero Halogen (LSZH) cables are manufactured to pass CPR (Construction Products Regulation) Class Dca whilst other cable manufacturers may only pass Eca. An Eca test is a basic test that only measures vertical flame spread. In addition to this test, Dca has a requirement to test for toxic fumes (acid gas), smoke and flaming droplets, making the CORE LSZH jacket superior.
Specifications
Product Construction
| |
---|---|
Conductor Material
|
Bare Copper
|
AWG Size
|
23 |
Conductor Category
|
Class 1 = Solid
|
Number of Pairs
|
4 |
Insulation Material
|
High-Density Polyethylene (HDPE) |
Overall Screening | Braiding |
Conductor Screening | Aluminium Foil for each pair |
Pair Colours
|
Blue, Blue/White; Orange, Orange/White; Green, Green/White; Brown, Brown/White
|
Outer Sheath Material
|
Low Smoke Zero Halogen (LSZH)
|
Outer Sheath Colour
|
Yellow |
Rip Cord
|
Nylon
|
Flame retardant according to IEC 60332-1-2 | Yes
|
Reaction-to-fire class according to EN 13501-6
|
Dca |
Smoke development class according to EN 13501-6
|
s2 |
Euro class flaming droplets/particles according to EN13501-6
|
d2 |
Euro class acidity according to EN 13501-6
|
a2 |
Standards | ANSI TIA/EIA 568.2-D, ISO/IEC 11801, IEC 61156, EN 50173, EN 50288, IEC 60332, IEC 60754, IEC 61034, EN 50575, RoHS-3
|
Mechanical Characteristics
| |
---|---|
Overall Diameter
|
7.8mm ± 0.10mm
|
Temperature Range
|
-20°C to +75°C
|
Max. Pulling Load
|
60 N/6.1 KgF
|
Bend Radius Installation
|
8x Overall Diameter
|
Bend Radius Installed
|
4x Overall Diameter
|
Electrical Characteristics
| |
---|---|
Max. Operating Frequency
|
1000MHz
|
Max. Conductor DC Resistance
|
≤ 9.38 Ω/100m @ 20°C
|
Pair-to-Ground Capacitance Unbalanced
|
≤330pF/100m
|
Max. Resistance Unbalanced
|
< 2.0%
|
Max. Insulation Resistance
|
> 5000 MΩ*km
|
Mutual Capacitance
|
< 5.6 nF/100m
|
Impedance @ 100MHz
|
100 Ω ± 15
|
Nominal Velocity of Propagation (NVP)
|
76%
|
Delay Skew
|
< 25 ns / 100m
|
Max. Operating Voltage
|
72V
|